General information, Refrigeration and temperature control, Adjusting the temperature – Perlick PS60 User Manual

Page 5: Cleaning the cabinet, Cleaning the condenser, Condenser, Recommended cleaning agents

Advertising
background image

JOb

CLEANING AGENT*

COmmENTS

routine Cleaning

Soap, ammonia, detergent

apply with sponge or cloth.

Can be used on all finishes.

Fingerprints and smears

areal 20, Lac-O-nu, Lumin Wash,

Provides barrier film to minimize

O’Cedar Cream Polish

fingerprints. Can be used on all finishes.

Stubborn stains and

allchem Concentrated Cleaner,

rub lightly, using dry or damp

Discolorations

Samae, twinkle, Zud restoro,

cloth in the direction of polish

grade F or FFF italian Pumice,

lines on the stainless steel.

Whiting or talc, Liquid nu Steel,

Copper’s or revere Stainless Steel

Cleaner, Lumin Cleaner, Sta-Clean,

Cameo Copper Cleaner, allen Polish

highlite, Penny-brite, Copper brite

5

Perlick is committed to continuous improvement. therefore, we reserve the right to change specifications without prior notice.

general information

Form no. Z2279

rev 08.01.07

Refrigeration and Temperature Control

the cabinet is equipped with a heavy-duty
refrigeration system designed to automatically
maintain a storage temperature of 36-41 degrees F.
the control is factory set at 38 degrees F.

Adjusting the temperature

the temperature control is inside the cabinet on
the left-hand side of the evaporator fan panel
assembly. You will need a screwdriver to turn the
adjusting screw. Make small adjustments until the
desired temperature is achieved.

Colder Temperatures:

turn the adjusting screw clockwise (to the right).

Warmer Temperatures:

turn the adjusting screw counterclockwise

(to the left).

Temperature Control “Off”:

turn the adjusting screw completely counter-

clockwise to the “O” position until a click is

noted.

the condenser fan motor turns off and on with
the compressor. the evaporator fan motor is on
all the time.
NOTE:
Cabinet temperatures lower than 34° will not
allow for proper defrosting of the evaporator coil. if
defrosting is necessary, turn the control knob to the
OFF position until coil is defrosted.

Cleaning the Cabinet

Use a mild detergent and water to clean the inside
and outside of the cabinet. Dry thoroughly. never
use a scouring pad or abrasive cleanser.
NOTE: an industrial strength, commercial cleaner
can be used to clean the outside of painted
cabinets.

Cleaning the Condenser

Use a long handled, stiff brush to clean the dirt
from the front surface of the condenser. Keeping
the condenser free from dust and dirt will ensure
efficient operation.
CAUTION: Do not bend the fins while brushing the
front of the condenser.

Condenser

the condenser (located behind the front grille
cover) should be inspected every 30 days and
cleaned, if necessary.

Failure to keep the condenser clean will cause a
loss in condensing unit efficiency.

1

2

3

4

5

6

OFF

COLD

COLDer

Recommended Cleaning Agents

* Use of propriety names is intended only to indicate a type of cleaner and does not constitute an endorsement.Omission of

any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on

the package.

nOte: Do not Use Steel Wool or Scouring Pads to clean stainless steel.

Advertising
This manual is related to the following products: