Wiring the restoration 5.1 – ProForm 831.210051 User Manual

Page 10

Advertising
background image

1.

Remove the two indicated Control Unit Screws (19)
and the two Small Star Washers (8) from the cover
on the Control Unit (14). Fold the cover down.

Route the 240 volt AC power cord through the indi-
cated opening on the right side of the Control Unit
(14).

2.

Attach the 240 volt AC power cord to the indicated
wires inside the Control Unit (14) as shown in the
diagram to the right.

3.

Determine if the 240 volt AC power supply in the home is a 30 amp supply or a 40 amp supply.

If the home power supply is a 30 amp supply, go to step 4.

If the home power supply is a 40 amp supply, go to step 5.

4.

For a 30 amp, 240 volt AC power supply, set the
jumper J1 to pins 2 and 3 on the power board and
leave the other jumpers at the factory settings, as
shown at the right. At 30 amps, there is not enough
amperage to operate the heater and the pump at
high speed simultaneously. Go to step 6.

1

2

N

White

Blue

Black

Black

Green

Blue

White

Wire Nut

L1

L2

14

4

Jumper settings for a 240 volt AC,

30 amp power supply

10

WIRING THE RESTORATION 5.1

The RESTORATION 5.1 is designed to operate with a 240 volt AC power source; it must be wired by a qualified
electrician directly into a 240 volt AC GFCI in your home. The steps below are intended to be used as a reference
for the qualified electrician who wires your spa and installs the 240 volt AC GFCI in your home. WARNING: Only
a qualified electrician should perform this procedure.

14

8

19

Wire Nut

Wire

Nut

240 volt AC Power Cord

Feed the

power cord in

through this

opening

Advertising