27

Press the MENU-UP button or MENU-DOWN
button to move the cursor to the NO position,
and press the SET button.
The menu protection mode is now released.

3

Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is now set to the menu protection mode.
When the LOCAL/MENU/REMOTE switch is set
to the MENU position, the unit is not set to the
menu setting mode, and “MENU PROTECTED”
appears on the video monitor screen.

<Note>
If, during the setting of the menu protection
mode, the LOCAL/MENU/REMOTE switch is set
to the MENU position while the COUNTER button
on the front panel is held down, the unit is set to
the menu setting mode, and the regular menu
settings can be performed.
Perform steps

2

to

7

of “Setting method using

the on-screen menus.”

5

Setup (initial settings)

Releasing the menu protection
mode

Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the
COUNTER button on the front panel.
The unit is set to the menu setting mode, and the
menu screen appears on the video monitor.

1

2

MENU PROTECT OK?

2

NO

YES

Perform steps

2

and

3

of the menu protection

procedure described above.
The screen prompting the user to confirm
whether to initiate menu protection appears on
the video monitor.

Displaying the DIAG menu

Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the EJECT
button.
The unit is set to the DIAG display mode, and the
hour meter and deck serial No. appear on the
video monitor.

1

Items with “r” can be reset when the unit is
serviced.

DIAG–MENU

HOURS METER

Ser

222222222

H00

OPERATION

00000H

H01

DRUM RUN

00000H

H02

TAPE RUN

00000H

H03

THREADING

00000T

H04

F LOADING

00000T

H11

DRUM RUN r

00000H

H12

TAPE RUN r

00000H

H13

THREADING r

00000T

H14

F LOADING r

00000T

With the hour meter displayed, press the
SEARCH button.
The software version appears on the video
monitor.

2

The hour meter display is restored when the
SEARCH button is pressed again.

DIAG–MENU

SOFT VERSION

SYSIF

1.

22

-

22

-

2

.

22

AVDV

1.

22

-

22

-

2

.

22

SERVO

1.

22

-

22

-

2

.

22

END

Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is restored to its regular mode.

3

The unit comes with a function for displaying the “hour
meter,” “software version” and “deck serial No.” on the
video monitor.

Advertising
This manual is related to the following products: