Technical specifications – PowerDsine PD-6006 User Manual

Page 14

Advertising
background image

PD-6006/12/24

Power over LAN Solutions

14

Cat. No.: 06-6800-056

Table 3-1: Troubleshooting Steps

Symptom

Corrective Steps

Is it safe to keep
the Midspan
running while a port
indicator is orange?

This is a safe condition. The orange indication is due to:

1. A device, not compliant to IEEE 802.3af, was detected.
2. Terminals 4/5 and 7/8 are shorted together.
3. Forced external power fed into the port.

During these conditions, port power is disconnected.

Technical Specifications

Physical Specifications

Dimensions

44 x 433 x 302 mm

(h x w x l)

(1.75 x 17 x 11.9 inch)

Weight

4 kg (8.8 lb)

Environmental Specifications

Temperature

- Operating

0 to 40 °C (32 to 104 °F)

- Storage

-20 to 70 °C (-4 to 158 °F)

Humidity

10 to 90% (non-condensing)

Electrical Specifications

Parameter

PD-6006

PD-6012

PD-6024

AC Input Voltage

90 to 264 VAC at 47-63 Hz

DC Input Voltage

46 to 57 VDC

Input Current @ 115 VAC

4 A max.

Input at 48 VDC

10 A max.

Total Output Power (1)

92 W max.

200 W max.

200 W max.

Output Power, per Port

15.4 W (not to exceed Total Output Power)

Nominal Output Voltage

44 to 57 VDC

Total Output Power (2)

400 W

(1) Using AC Power

(2) Using DC power

Advertising