Parameter format

Parameter format

Size (Byte)

Difinition

<pl>

<off on>

<input signal>

<installation>

<language>

<power condition>

<lamp condition>

<acctch>

<color temp>

<date>

<time>

3 (1 or 2 bytes also

possible when

under control)

1

3

1

3

3

1

4

1

8

6

Dicimal without signs: 0-999 (000, 001, 002...999)

Dicimal with signs: -99 to +99 (-99...-01, +00, +01, +02...+99)

Callback from the projector is 3 Byte.

0 = off, 1 = on

RG1 = computer 1, RG2 = computer 2, NWP = network,

YUV = component, VID = video, SVD = S-Video

0 = front, 1 = rear, 2 = ceiling and front, 3 = ceiling and rear

ENG = English, DEU = German, FRA = French, ESP = Spanish,

ITL = Italian, JPN = Japanese, CHI = Chinese, POR = Portuguese,

SVE = Swedish, NOR = Norwegian, DAN = Danish, POL = Polish,

CES = Czech, MAG = Hungarian, RUS = Russian, THA = Thai, KOR = Korean

000 = power on (standby mode on), 001 = power off (standby mode off)

0 = standby, 1 = lamp on under control, 2 = lamp off,

3 = lamp off under control

Dicimal without signs: 0000-9999 hours

0 = economy, 1 = normal

y1y2y3y4m1m2d1d2w = year (y) month (m) day (d) day of week (w)

Day of week: Monday = 1, Tuesday = 2, ... Sunday = 7

h1h2m1m2s1s2 = hour (h) minute (m) second (s)

Command example

To set the volume to +30, send the command as shown below.

STX

AVL

:

30

ETX

Start

Command

Parameter

End

NOTE: If a wrong command is received, the projector will send an ER401 command to the computer.

NOTE: When sending commands without parameters, a colon (:) is not necessary.