Pentair 75 User Manual

Page 19

Advertising
background image

19

Rev. E 5-16-01

P/N 471105

Installation (contd.)

MiniMax 100 Electronic Direct Spark Ignition Wiring Diagram

THERMAL
FUSE

HI LIMIT SW.

PRESSURE SW.

WATER

THERMOSTAT

ON/OFF SW.

IGNITER

SPARK

MODULE

GAS VALVE

MiniMax 100 ELECTRONIC WIRING DIAGRAM

CODE OR SUPERCEDING LOCAL (WIRING) CODES.

INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL

WIRE, 18 GAUGE, 600V, 150˚ C TEMPERATURE RATING..

THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED

UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 150˚ C TEMPERATURE RATING.

IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY

TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE

GROUND SCREW WITH PAINT CUTTING WASHER

EXTERNAL
BOND LUG

CHASSIS
SHEET METAL

V1

TH

V2/GRD

N

H

GRN

WHT

BLUE

WHT

ORN

ORN

GRN

WHT

WHT

WHT

WHT

WHT

WHT

ELECTRONIC

1

2

3

4

TRANSFORMER WIRING :

115V CONN

LINE : 1 & 2 (TIED)

LINE : 3 & 4 (TIED)

230V CONN

2 & 3 (TIED)

LINE : 1

LINE : 4

WHT/RED

WHT/BLK

BLK

RED

MiniMax 100 Millivolt Wiring Diagram

Remote Wiring Hook-up

The MiniMax 100 may be
connected to a two wire remote
control by disconnecting the wire
connector from the hot
(transformer) side terminal of the
"ON/OFF" switch and connecting
the two wire remote across the end
of this wire and the aforementioned
terminal.

NOTE

When connecting a remote control
to the MiniMax 100 you must install
the low voltage remote control
wires in a separate conduit from
ANY line voltage wires. Do not
exceed 25 ft. wire run for remotes
on millivolt models.