Max Operating Pressure

Model

ins

C

mm

ins

mm

ins

mm

Pipe Size

A

B

kg

lbs

Weight

005A

1

/

4

"

76

3.0

154.5

6.1

126.5

5.0

0.5

1.1

005B

1

/

4

"

76

3.0

154.5

6.1

126.5

5.0

0.5

1.1

005C

1

/

4

"

76

3.0

154.5

6.1

126.5

5.0

0.5

1.1

010A

1

/

4

"

76

3.0

181.5

7.2

153

6.0

0.4

0.88

010B

3

/

8

"

76

3.0

181.5

7.2

153

6.0

0.4

0.88

010C

1

/

2

"

76

3.0

181.5

7.2

153

6.0

0.4

0.88

015B

3

/

8

"

97.5

3.8

235

9.3

201

7.9

1

2.2

015C

1

/

2

"

97.5

3.8

235

9.3

201

7.9

1

2.2

020C

1

/

2

"

97.5

3.8

235

9.3

201

7.9

1

2.2

020D

3

/

4

"

97.5

3.8

235

9.3

201

7.9

1

2.2

020E

1"

97.5

3.8

235

9.3

201

7.9

1

2.2

025D

3

/

4

"

129

5.1

275

10.8

232.5

9.2

2.2

4.84

025E

1"

129

5.1

275

10.8

232.5

9.2

2.2

4.84

030E

1"

129

5.1

364.5

14.3

322

12.7

2.6

5.72

030F

1

1

/

4

"

129

5.1

364.5

14.3

322

12.7

2.6

5.72

030G

1

1

/

2

"

129

5.1

364.5

14.3

322

12.7

2.6

5.72

035F

1

1

/

4

"

170

6.7

432.5

17.0

382.5

15.1

4.5

9.9

035G

1

1

/

2

"

170

6.7

432.5

17.0

382.5

15.1

4.5

9.9

040G

1

1

/

2

"

170

6.7

524.5

20.6

474.5

18.7

5.25

11.55

040H

2"

170

6.7

524.5

20.6

474.5

18.7

5.25

11.55

045H

2"

170

6.7

524.5

20.6

474.5

18.7

5.25

11.55

050I

2

1

/

2

"

205

8.1

641.5

25.3

581.5

22.9

10

22

050J

3"

205

8.1

641.5

25.3

581.5

22.9

10

22

055I

2

1

/

2

"

205

8.1

832

32.8

772

30.4

12

26.4

055J

3"

205

8.1

832

32.8

772

30.4

12

26.4

Weights and dimensions

Filter Grade

Filter Models

Max Recommended

Operating Temp

Min Recommended

Operating Temp

bar g

psi g

AO

005

F

- 055

F

16

232

80ºC

176ºF

1.5ºC

35ºF

AO

005

M

- 055

M

20

290

100ºC

212ºF

1.5ºC

35ºF

AA

005

F

- 055

F

16

232

80ºC

176ºF

1.5ºC

35ºF

AA

005

M

- 055

M

20

290

100ºC

212ºF

1.5ºC

35ºF

AR

005

M

- 055

M

20

290

100ºC

212ºF

1.5ºC

35ºF

AAR

005

M

- 055

M

20

290

100ºC

212ºF

1.5ºC

35ºF

ACS

005

M

- 055

M

20

290

50ºC

122ºF

1.5ºC

35ºF

Technical data

Incident Monitor

Used to indicate premature high differential pressure.
Indicator can be retrofitted to existing housings without
depressurising the system.

FXKE Fixing Clamp

Fixing clamp allows quick and simple
connection of multiple filter housings.

MBKE Mounting Brackets

Mounting brackets provide additional support to filters
installed in flexible piping systems or OEM equipment.

Filter Fixing Kits

Filter Model

005 - 010

FXKE1

015 - 020

FXKE2

025 - 030

FXKE3

035 - 045

FXKE4

050 - 055

FXKE5

MBKE Mounting Bracket Kits

Filter Model

005 - 010

MBKE1

015 - 020

MBKE2

025 - 030

MBKE3

035 - 045

MBKE4

050 - 055

MBKE5

Incident Monitor

Filter Model

015 - 055

DPM