Aging exception, Filled address table, Introduction – Perle Systems IOLINK-PRO IOLINK-520 User Manual

Page 16

Advertising
background image

Introduction

IOLINK-PRO & 520 Reference Manua —

1.15

Aging Exception

“Permanent” address entries are an exception to the aging rule. A permanent address is one that is not subject to the

aging timer and will remain in the filter table for an indefinite period of time.

A table is reserved for permanent address entries, separate from the table that is used for those non-permanent

entries that are subject to aging. These tables may be displayed and modified with the bridge/router options

discussed in this manual. Access is made locally from each Bridge/Router Console or one bridge/router can be made

Master, able to control all functions of a partner IOLINK router.

Filled Address Table

The filter table can hold 2048 address entries.If filter address table becomes filled, the following automatic procedure is

followed:

This procedure defines that an address that is not in the table will not be added and will be treated as any other unknown

address. The frame will be passed to the other segment. An alarm will also be generated with the message “Station Address

Table Full,” and from this point, another alarm will be generated only if in the meantime the table empties by 1/3 and then

fills up again.

Advertising