background image

Hardware installation

31

Models 2603, 2621, and 2635 User Manual

3 • Initial Configuration

Installing an interface cable on the OnSite 2621’s X.21 interface port
The OnSite Model 2621 comes with an X.21 interface presented on a female DB-15 connector (see

figure 7

).

This interface can be configured as a DTE (factory default), or as a DCE via internal configuration jumper.

Figure 7. Rear view of the 2621 showing location of Ethernet and X.21 connectors

The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.

CAUTION

Crossover

10/100

Ethernet

Power

X.21 Interface

MDI-X

MDI-X

Crossover

10/100

Ethernet

Power

X.21 Interface

X.21 Interface connector

(DB-15)

Ethernet connector

(RJ-45)

Advertising