INSTALLATION

Positioning

Remove all the packaging and install the cooker
in a dry well, ventilated room away from curtains,
paper, alcohol, petrol etc. (See figure).

This appliance is approved to class “1” regarding
overheating of surrounding surfaces.

It is mandatory to keep 20 mm distance from the
adjacent furniture.

L.P.G. cookers or ovens MUST NOT be

installed below ground level, i.e. in a
basement, or aboard any boat, yacht or
other vessel.

The cooking appliance must be fitted

with a stability chain firmly secured to
the wall (see fig)

20 mm

20 mm

610 mm

Pro

line

21

345678

G

150 mm

660 m

m

Stability

chain

Stability

hook

Chain to be as

short as

practicable

Firmly fix

chain to rear

of cooker

Ventilation

The room containing the cooker should have an
air supply in accordance with B.S. 5440: Part 2:
Current Editions.
The following requirements for ventilation must
be met.
The cooker should not be installed in a bed
sitting room with a volume of less than 20m

3

, if it

is installed in a room of volume less 5m

3

an air

vent of effective area of 110cm

2

is required; if it is

installed in a room of volume between 5m

3

and

10m

3

, an air vent of effective area 50cm

2

is

required, while if the volume exceeds 11m

3

no air

vent is required. However, if the room has a door,
which opens directly to the outside, no air vent is
required even when the volume is between 5m

3

and 11m

3

.

Fitting the adjustable feet

Unpack the support brackets with the feet
attached.Place a piece of cloth/cardboard onto
your floor to protect both your floor and the
cooker.
Lay the cooker on its back, fit the support
brackets (see fig) using the bolts, washers and
nuts supplied and ensure that the nuts are tight.
lift the cooker upright onto its feet.

If there are other fuel burning appliances in the
same room, B.S. 5440: Part. 2: Current Editions
should be consulted to determine the requisite air
vent requirements.

Location

The cooker may be located in a kitchen, a
kitchen/diner or bed sitting room but not in a
bathroom, shower room or garage.
For information regarding the fitting of flexible
supply pipes, the highest temperature at the rear
of this cooker which may come into contact with
the supply pipe is 70°C above ambient.

L.P.G. cookers or ovens MUST NOT be

installed below ground level, i.e. in a
basement, or aboard any boat, yacht or other
vessel.