Panasonic SJ-MJ88 User Manual

Page 29

Advertising
background image

4. Press the

key of the remote controller (“LD ” changes to “LP ” of the

LCD).

5. Set the laser power at 600 W±10% by using VOL+ and VOL- key of the

remote controller.
[Specified range: 600 W±10%]

Caution:

Proceeding on to the subsequent adjustment procedure with the read power
exceeding 600 W±10% will result in damage to the optical pickup.

6. Set the laser power with the

key of the remote controller (“LP ” changes

to “LDOK ” in the LCD).

7. Press the

key of the remote controller (“LDOK ” changes to “T0E ” on

the LDC.

8. Remove the laser power meter. Laser power adjustment is finished.

[REFERENCE]
<For use of MD cartridge type laser power meter>
We recommend you to use a sensor type laser power meter for laser power
adjustment of this set.
But if available is a MD cartridge type only, follow the procedure below.

1. Disassemble the unit so that only the mechanism unit and the printed circuit

board are exposed. (as shown in

Fig. 8

)

2. Set the laser power meter cartridge. (as shown in

Fig. 8

)

3. Set the battery and attach and secure the battery cover with a rubber band.

(as shown in

Fig. 9

)

4. Follow the steps for “6.2.1. Enter the adjustment mode”. (Subsequent

procedures are the same as those for the sensor type.)

Fig. 8

29

Advertising