Paradyne U8777 User Manual

Page 110

Advertising
background image

A. Configuration Options

A-14

May 2002

8700-A2-GB20-40

Test Duration (min)

Possible Settings: 1 – 120
Default Setting: 10

Number of minutes for a test to be active before automatically ending.

T

Test Duration (min) option appears when Test Timeout is enabled.

1 – 120 – Amount of time in minutes for a test to run before terminating.

Telco Initiated Loopback

(Model 8777)
Possible Settings: Enable, Disable
Default Setting: Enable

Determines if the unit will respond to Telco loopback commands on the DSX-1 interface.
See

Telco-Initiated Tests

in Chapter 8,

Testing

.

Enable – The unit will respond to Telco loopback commands.

Disable – The unit will not respond to Telco loopback commands.

Remote Telco Line Loopback

(Model 8777)
Possible Settings: Enable, Disable
Default Setting: Disable

Determines if the unit will perform a Telco initiated loopback on just the local unit or if the
loopback will be performed on the remote DSL unit. See

Telco-Initiated Tests

in Chapter 8,

Testing.

Enable – The loopback will be in the remote unit.

Disable – The loopback will be local.

G.703 Line Termination

(Model 8779)
Possible Settings: 75 ohms, 120 ohms
Default Setting: 120 ohms

Specifies the impedance of the G.703 interface.

75 ohms – The G.703 interface impedance is 75 ohms unbalanced (for short-haul use
only).

120 ohms – The G.703 interface impedance is 120 ohms balanced.

Table A-7.

System Options (2 of 2)