System clock options, Table a-8 – Paradyne U8777 User Manual

Page 114

Advertising
background image

A. Configuration Options

A-18

May 2002

8700-A2-GB20-40

Table A-8.

System Clock Options

Primary System Clock Reference

Possible Settings (LTU, Model 8777): DSX-1 Port 1, DSX-1 Port 2, DSX-1 Port 3,
DSX-1 Port 4, DSX-1 Port 5, DSX-1 Port 6, DSX-1 Port 7, DSX-1 Port 8, Internal
Default Setting: Internal

Possible Settings (LTU, Model 8779): G.703 Port 1, G.703 Port 2, G.703 Port 3,
G.703 Port 4, G.703 Port 5, G.703 Port 6, G.703 Port 7, G.703 Port 8, Internal
Default Setting: Internal

Possible Settings (NTU): DSL Port 1, DSL Port 2, DSL Port 3, DSL Port 4, DSL Port 5,
DSL Port 6, DSL Port 7, DSL Port 8
Default Setting: DSL Port 1

Determines the source of system timing. Select the most accurate clock available.

DSX-1 Port

n

(Model 8777) – Timing is derived from the specified port. To be a valid clock

source, the port must be enabled and must derive its timing from the DSX-1 network.

NOTE: If the DSX-1 port is configured for Bypass mode, the Primary Clock Source
configuration option on the DSX-1 Interface Options screen must be set to DSX-1, not
Internal (see

Table A-4

). All ports configured as system clock sources must be

traceable to the same clock reference.

G.703 Port

n

(Model 8779) – Timing is derived from the specified port. To be a valid clock

source, the port must be enabled and must derive its timing from the G.703 network.

NOTE: If the G.703 port is configured for Bypass mode, the Primary Clock Source
configuration option on the G.703 Interface Options screen must be set to G.703, not
Internal (see

Table A-5

). All ports configured as system clock sources must be

traceable to the same clock reference.

DSL Port

n

– Timing is derived from the specified port. The port must be enabled and in a

cross-connection.

Internal – Timing is derived from the internal oscillator, which provides a Stratum 4
reference.

Secondary System Clock Reference

Possible Settings (LTU, Model 8777): DSX-1 Port 1, DSX-1 Port 2, DSX-1 Port 3,
DSX-1 Port 4, DSX-1 Port 5, DSX-1 Port 6, DSX-1 Port 7, DSX-1 Port 8, Internal
Default Setting: Internal

Possible Settings (LTU, Model 8779): G.703 Port 1, G.703 Port 2, G.703 Port 3,
G.703 Port 4, G.703 Port 5, G.703 Port 6, G.703 Port 7, G.703 Port 8, Internal
Default Setting: Internal

Possible Settings (NTU): DSL Port 1, DSL Port 2, DSL Port 3, DSL Port 4, DSL Port 5,
DSL Port 6, DSL Port 7, DSL Port 8
Default Setting: DSL Port 1

Determines the source of system timing if the primary system clock source fails. If the
secondary clock source fails, the unit switches to the internal clock.

DSX-1 or G.703 Port

n

– Timing is derived from the specified port. To be a valid clock

source, the port must be enabled and must derive its timing from the DSX-1 or G.703
network.

DSL Port

n

– Timing is derived from the specified port. The port must be enabled.

Internal – Timing is derived from the internal oscillator, which provides a Stratum 4
reference.