Paradyne U8777 User Manual

Page 123

Advertising
background image

A. Configuration Options

8700-A2-GB20-40

May 2002

A-27

Start TS

Possible Settings (Model 8777): 1 – 24
Default Setting: [Blank]

Possible Settings (Model 8779): 1 – 31
Default Setting: [Blank]

Specifies the time slot where time slot assignment is to begin in the contiguous time slots
specified in the DS0s to Allocate option for the selected port. Only unassigned time slots
can be selected.

1 – 31 – The number of the first time slot that can be assigned.

Assign To

Possible Settings (Model 8777): D, X
Default Setting: D

Possible Settings (Model 8779): D, G
Default Setting: D

Assigns the corresponding port and beginning time slot specified in the DS0s to Allocate
and Start TS options to a Port Type and Data or Voice setting. After the time slot is
assigned, the Data or Voice setting can be changed.

D – The time slot is assigned to a DSL port.

G – The time slot is assigned to a G.703 port (Model 8779).

X – The time slot is assigned to a DSX-1 port (Model 8777).

Time Slot Number

Possible Settings (Model 8777): 1 – 24
Default Setting: [Blank]

Possible Settings (Model 8779): 1 – 31
Default Setting: [Blank]

Determines the time slot to which this time slot is connected.

1 – 31 – The time slot to be assigned.

Data or Voice

Possible Settings: d, v
Default Setting: d

Determines whether the time slot is dedicated to the transmission of voice or data.

d – The time slot is used for data.

v – The time slot is used for voice.

Table A-11. Assign Time Slots Options (2 of 2)