Setting the cross-connect modes – Paradyne U8777 User Manual

Page 40

Advertising
background image

4. Cross-Connecting Ports

4-4

May 2002

8700-A2-GB20-40

Setting the Cross-Connect Modes

To access the Set Cross-Connect Mode screen, follow this menu selection
sequence:

Main Menu

Configuration

Current Configuration

Cross-Connect

Set Cross-Connect Mode

When the screen is first displayed, all ports are set to DS1 Bypass mode. In this
example, Ports 1 and 2 have been changed to

DS0 Cross-connect

, and

Ports 3 –8 have been changed to

DS1 Bypass

.

Unassigned

appears next to

Ports 1 and 2 because time slots associated with the cross-connection have not
yet been assigned.

main/config/xconnect_mode

Slot: 18 Model: 8777

CROSS-CONNECT MODE

DSX-1 Port MODE DSL Port

1 DS0 Cross-connect Unassigned

2 DS0 Cross-connect Unassigned

3 DS1 Bypass 3

4 DS1 Bypass 4

5 DS1 Bypass 5

6 DS1 Bypass 6

7 DS1 Bypass 7

8 DS1 Bypass 8

Assign_DS0s

-------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save Clear_All

Advertising
This manual is related to the following products: