System controller display i, System controller display information – Panasonic WJ-SX650 User Manual

Page 14

Advertising
background image

14

Notes:

• During the alarm acknowledgement (ACK) status (refer

to p.

31

), event information is highlighted.

• When two or more alarm events have occurred, "

∗" is

displayed beside the event.

• When an alarm occurs and its display mode setting is

OFF (refer to p.

30

), "#" is displayed beside the event

information.

• When auto tracking is scheduled for a camera event, "#"

is displayed beside the camera number.

• q to r can be displayed or hidden either altogether or

separately. Refer to p.

36

Lists of Functions and

Operations for details.

System Controller Display

Information

The following are the details on terminal mode operations.
For PS·Data operations, refer to p.

48

OPERATION (OTHER

THAN THE TERMINAL MODE) or the operating instructions
of system controllers.

WV-CU950/650

q Monitor Number

Mon01 to 32: Monitor number

w Camera Number

Cam001 to 999: Camera number
C-P0001 to 9999: Camera position number

e Event

HDR01 to 16: Recorder number
Pre000 to 256 (Lighting for 3.0 seconds): Preset position
Note: Pre000 is the home position.

T-A0001 to 0256: Terminal alarm
C-A0001 to 0999: Camera alarm
R-A0001 to 0999: Recorder alarm
S-A0001 to 1024: Serial alarm
V-A0001 to 0999: Video loss

r Busy

Busy + monitor number (Blinking)
A selected monitor is controlled by a higher-level oper-
ator. (Monitor busy)
Note: You cannot control the selected monitor, camera,

and recorder.

Busy + camera/recorder number (Blinking)
A selected camera or recorder is controlled by a high-
er-level user. (Camera/Recorder busy)
Note: You cannot control the selected camera or

recorder.

t Status

Alarm (Blinking): Alarm is occurring.
Alarm (Lighting): Alarm is acknowledged. (Refer to p.

31

.)

Memory + preset position number (Blinking for 3.0 sec-

onds): Preset position is registered.

y Sequence Number

T-Seq01 to 32: Tour sequence number
G-Seq01 to 08: Group sequence number
Note: During sequence pause, "P" is displayed beside

the sequence number.

G-Seq09 to 32: Group preset number
Note: This sign disappears when the camera is con-

trolled.

Invalid (Blinking for 3.0 seconds): You have entered a

wrong value.

Not Avail (Blinking for 3.0 seconds):

• You cannot select a monitor because of lower priori-

ty.

• You have tried to activate a group sequence or

group preset on a monitor not assigned.

Prohibited (Blinking for 3.0 seconds): You have tried an

operation restricted by the level setting.

Alarm Buzzer/Button Buzzer Setting
With the setting activated:

• Alarm buzzer can sound when alarms occur.
• Button buzzer can sound when a button is pressed or

an error message (Invalid, Prohibited, Level1 Fixed,
etc.) is displayed on the LCD.
Refer to the operating instructions of system controller
for settings.

t

y

r

q

w

e