Rs-232c adjustment – Pioneer Plasma Display Panel PDP-425CMX User Manual

Page 6

Advertising
background image

6

Under the connection conditions shown below, use a combination cable for up to 16 panels.

Conditions:

1 Length of RS-232C cable connecting PC to PDP-425CMX/PDP-42MXE10: 5 m
2 Combination cable length: 5 m each
3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable)

For 1 strand, suitable for AWG28:

Cross-section area = 0.08 mm

2

7 strands

× π r

2

= 7

Ч 3.14 Ч 0.06

2

= 0.079 mm

2

≠ 0.08 mm

2

Note

For details on the number of displays that can be connected in series using the video OUT terminal (INPUT1, 4), refer to

section 2.3, “Controls and Connectors” (pg. 10) in the Technical Manual.

PC

RS-232C

Combination cable 5m

PDP-425CMX

PDP-42MXE10

1

2

3

#

OUT

IN

OUT

IN

OUT

IN

5m

RS-232C Adjustment

Advertising