Functional description, Replacement parts, Motor – Porter-Cable 900276 User Manual

Page 5: Extension cord selection, Foreword

Advertising
background image

REPLACEMENT PARTS

When servicing use only identical replacement parts.

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60
cycle A.C. current and voltage within plus or minus 5 percent of that shown
on the specification plate on the tool. Several models, however, are designed
for A.C. current only. Refer to the specification plate on your tool for proper
voltage and current rating.

CAUTION: Do not operate your tool on a current on which the
voltage is not within correct limits. Do not operate tools rated A.C.
only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to
prevent excessive voltage drop which will cause loss of power and possible
motor damage. A table of recommended extension cord sizes will be found
in this section. This table is based on limiting line voltage drop to 5 volts (10
volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors it must be marked with the suffix
W-A or W following the cord type designation. For example – SJTW-A to
indicate it is acceptable for outdoor use.

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

FUNCTIONAL DESCRIPTION

FOREWORD

The Porter-Cable Model 6602 Shear is designed for cutting cold rolled steel
sheets of up to 18 Ga. and stainless steel sheets of up to 20 Ga. Both
straight and curved cuts (minimum radius: 7") may be made. The Shear
removes a

¼

" wide, continuous curl of waste material without bending or

burring the finished workpiece.

The Porter-Cable Model 6604 Cement Siding Shear is designed for cutting
cement siding. Both straight and curved cuts (minimum radius: 7") may be
made. The Shear removes a

¼

" wide piece of waste material.

5

Length of Cord in Feet

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft. 1000 Ft.

0-2

18

18

18

16

16

14

14

12

12

2-3

18

18

16

14

14

12

12

10

10

3-4

18

18

16

14

12

12

10

10

8

4-5

18

18

14

12

12

10

10

8

8

5-6

18

16

14

12

10

10

8

8

6

6-8

18

16

12

10

10

8

6

6

6

8-10

18

14

12

10

8

8

6

6

4

10-12

16

14

10

8

8

6

6

4

4

12-14

16

12

10

8

6

6

6

4

2

14-16

16

12

10

8

6

6

4

4

2

16-18

14

12

8

8

6

4

4

2

2

18-20

14

12

8

6

6

4

4

2

2

Nameplate Ampere Rating

900276 - 10-31-01.qxd 2/13/02 8:33 AM Page 5

Advertising
This manual is related to the following products: