5 wiring the fault alarm contact – Planet Technology Planet 4-Port 10/100Mbps +1/2 100FX Fiber Port Industrial Fast Ethernet Switch ISW-621 User Manual

Page 18

Advertising
background image

1

2.1.5 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the Industrial
Fast Ethernet Switch will detect the fault status of the power failure,
or port link failure (available for managed model) and then forms an
open circuit. The following illustration shows an application example for
wiring the fault alarm contacts.

1

2

3

4

5

6

Insert the wires into the fault alarm contacts

Note

1. The wire gauge for the terminal block should be in

the range between 12 ~ 24 AWG.

2. Alarm relay circuit accepts up to 30V, max. 3A

currents.