Paradyne Hotwire ATM Line Cards 8385 User Manual

Page 98

Advertising
background image

5. Diagnostics

5-12

February 2003

8335-A2-GB20-70

Procedure

To test a virtual circuit:

1. Select an interface (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through

dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8385).

2. Enter a VPI and VCI for the virtual circuit you wish to test, the type of test

desired (end-to-end or segment), and the test direction (towards the endpoint
or towards the network).

3. Select Begin.

4. Interpret the display as shown in

Table 5-3, Diagnostics – ATM Ping

.

Table 5-3.

Diagnostics – ATM Ping

ATM Ping Screen

D-C-A

Displays the progressive results of sending of test cells to the ATM endpoint on a
selected virtual circuit.

Interface name – Select the interface to be tested (dsl1:1 through dsl16:1 on the
Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the
Model 8385).

VPI – Enter the VPI of the VC to be tested.

VCI – Enter the VCI of the VC to be tested.

Type – The type of test, either End2End (End-to-End F5 Loopback) or Segment
(Segment F5 Loopback).

Direction – Select the direction you wish to send cells to: Towards the Endpoint or
Towards the Network.

Status – Indicates whether a test is in progress (Active/Inactive).

Class – Displays the class of service for the selected VPI/VCI.

Source – If a ping test is in progress, displays the source of the test, either UI (from the
user interface) or NMS (from the NMS).

Elapsed Time – Displays the amount of time that has elapsed since the test began.

Cells Sent – Displays the number of cells sent on this VC. The counter restarts after
99999999.

Cells Received – Displays the number of cells received on this VC. The counter restarts
after 99999999.

Round Trip Delay:

Min – Displays the shortest round trip delay (0 to 99999 ms) encountered on cells
received.

Max – Displays the longest round trip delay (0 to 99999 ms) encountered on cells
received.

Avg – Displays the average round trip delay (0 to 99999 ms) encountered on cells
received.

Advertising