3.4 CONFIGURATION SWITCH APPLICATIONS

The switch settings

generally

needed to configure the Model 2085

for various applications are shown in the table below. Note: Do not
change switch settings until you have

carefully

read Section 3.3.

S1-4: Echo Mode

The setting for switch S1-4 determines whether the Model 2085

echoes data back to the transmitting device (half-duplex mode only).

S1-4

Setting

On

Echo On

Off

Echo Off

S1-5: Carrier Control Method

The setting for switch S1-5 determines whether the carrier is

“Constantly On” or “Controlled by RTS”. This setting allows for
operation in switched carrier, multipoint and/or hardware handshaking
applications.

S1-5

Setting

On

Controlled by RTS

Off

Constantly On

S1-6: Receive Impedance

The setting for switch S1-6 selects the impedance of the input

receiver. You may select either a “low” impedance of 120 Ohms or a
“high” impedance of 16 kOhms. By selecting the proper impedance for
each drop, there may be up to 50 receivers in one application.

S1-6

Setting

On

Low (120 Ohm)

Off

High (16 kOhm typical)

S1-7 and S1-8: 2-Wire/4-Wire Modes

Switches S1-7 and S1-8 are set together to determine whether the

Model 2085 is in 2-wire or 4-wire operating mode. Note: 2-wire mode
is half-duplex only.

S1-7

S1-8

Setting

On

On

2-wire mode

Off

Off

4-wire mode

7

8

S1-1: “Xmt Off” Imp.

OFF

OFF

OFF

OFF

OFF

S1-2: “Xmt Off” Imp.

OFF

OFF

OFF

OFF

OFF

S1-3: RTS/CTS Delay

ON

ON

ON

OFF

ON

S1-4: Echo

OFF

OFF

OFF

OFF

OFF

S1-5: Carrier Control

OFF

ON

ON

Master-OFF

ON

Slaves-ON

S1-6: Rcv Impedance

ON

ON

ON

Master - ON

Slaves - OFF

Last Slave - ON

S1-7: 2-wire/4-wire

OFF

OFF

ON

OFF

ON

S1-8: 2-wire/4-wire

OFF

OFF

ON

OFF

ON

TYPICAL MODEL 2085 APPLICATIONS

Point-to-Point

Switch

Settings

Multi-point

4W

2W

4W

2W

4W HDX

Advertising