Connections, Connection with the main cpus, Connection with the rs-485 system controllers – Panasonic WJ-MPS850 User Manual

Page 4: Satellite standalone yes no, Push

Advertising
background image

-4-

Connections

Connection with the Main CPUs

Connect with the Main CPUs A and B as shown in
the figure.

• Connect RS-485 modular cables between controller

ports (RS-485) of the CPUs and controller ports (RS-
485) of this unit.

• Connect diagnostic cables between parallel ports of

the CPUs and diagnostic input ports of this unit.

• Set the redundant CPU selector to YES on the rear

of A and B CPUs.

Connection with the RS-485

System Controllers

Connect with the RS-485 system controllers as
shown in the figure.

PUSH

FUSE

AC IN

TARGET

DATA 1

MAIN CPU-ACT

CAITION

MAIN CPU-STANDBY

PERIPHERAL INTERFACE (RS-232C)

SYSTEM CONTROLLER (RS-485)

DIAGNOSTIC

INPUT

DATA 1

DATA 2

DATA 2

DATA 3

DATA 3

DATA 4

DATA 4

DATA 5

DATA 5

DATA 6

DATA 6

DATA 7

DATA 7

DATA 8

DATA 8

DATA 9

DATA 9

DATA 10

DATA 10

DATA 11

DATA 11

DATA 12

DATA 12

3

2

1

3

2

1

3

2

1

DATA 1

DATA 2

DATA 3

DATA 4

DATA 5

DATA 6

DATA 7

DATA 8

DATA 9

DATA 10

DATA 11

DATA 12

PARALLEL

SATELLITE

MODE

REDUNDANT

CPU

ETHERNET

1

CAMERA

CROSS POINT

OSD

GYGTEM

CONTROLLER

DATA 6

DATA 5

DATA 4

DATA 3

DATA 2

DATA 1

PERIFERAL INTERFACE (RS–232C)

(RS–485)

SYSYTEM

CONTROLLER

2

3

SATELLITE

STANDALONE

YES

NO

AC IN

Central Processing Unit

SIGNAL
GND

PARALLEL

SATELLITE

MODE

REDUNDANT

CPU

ETHERNET

1

CAMERA

CROSS POINT

OSD

GYGTEM

CONTROLLER

DATA 6

DATA 5

DATA 4

DATA 3

DATA 2

DATA 1

PERIFERAL INTERFACE (RS–232C)

(RS–485)

SYSYTEM

CONTROLLER

2

3

SATELLITE

STANDALONE

YES

NO

AC IN

Central Processing Unit

SIGNAL
GND

A CPU

B CPU

PUSH

FUSE

AC IN

TARGET

DATA 1

MAIN CPU-ACT

CAITION

MAIN CPU-STANDBY

PERIPHERAL INTERFACE (RS-232C)

SYSTEM CONTROLLER (RS-485)

DIAGNOSTIC

INPUT

DATA 1

DATA 2

DATA 2

DATA 3

DATA 3

DATA 4

DATA 4

DATA 5

DATA 5

DATA 6

DATA 6

DATA 7

DATA 7

DATA 8

DATA 8

DATA 9

DATA 9

DATA 10

DATA 10

DATA 11

DATA 11

DATA 12

DATA 12

3

2

1

3

2

1

3

2

1

DATA 1

DATA 2

DATA 3

DATA 4

DATA 5

DATA 6

DATA 7

DATA 8

DATA 9

DATA 10

DATA 11

DATA 12

OPERATE

LINK

ALARM

MONITOR

CAMERA

BUSY

PROHIBITED

PROGRAM

PRESET

IRIS

System Controller WV-CU

350

For Matrix Switcher (System 850)

OPEN

CLOSE

AUTO IRIS

CALL

PRESET

AUX1 OFF

CAM ID

AUX1 ON

RESET

ACK

NEXT

PREV

S-CTL ID

STOP

PAUSE

CAM MENU ON

CAM MENU OFF

TOUR

SEQ

GROUP

SEQ

MONITOR

LOCK

OSD

ALARM

DISARM

ALL RESET

OPE ID

GROUP
PRESET

LOG OUT

F1

F2

GEN

WIPER

AUX2 OFF

MON STATUS

AUX2 ON

ALL

SHIFT

CLEAR

(ESC)

DEF OFF

DEF ON

CAMERA

(ENTER)

AUTO

PAN

FOCUS

FAR

NEAR

AUTO FOCUS

ZOOM

DOWN

UP

R

L

TELE

WIDE

OPERATE

LINK

ALARM

MONITOR

CAMERA

BUSY

PROHIBITED

PROGRAM

PRESET

IRIS

System Controller WV-CU

350

For Matrix Switcher (System 850)

OPEN

CLOSE

AUTO IRIS

CALL

PRESET

AUX1 OFF

CAM ID

AUX1 ON

RESET

ACK

NEXT

PREV

S-CTL ID

STOP

PAUSE

CAM MENU ON

CAM MENU OFF

TOUR

SEQ

GROUP

SEQ

MONITOR

LOCK

OSD

ALARM

DISARM

ALL RESET

OPE ID

GROUP
PRESET

LOG OUT

F1

F2

GEN

WIPER

AUX2 OFF

MON STATUS

AUX2 ON

ALL

SHIFT

CLEAR

(ESC)

DEF OFF

DEF ON

CAMERA

(ENTER)

AUTO

PAN

FOCUS

FAR

NEAR

AUTO FOCUS

ZOOM

DOWN

UP

R

L

TELE

WIDE

OPERATE

LINK

ALARM

MONITOR

CAMERA

BUSY

PROHIBITED

PROGRAM

PRESET

IRIS

System Controller WV-CU

350

For Matrix Switcher (System 850)

OPEN

CLOSE

AUTO IRIS

CALL

PRESET

AUX1 OFF

CAM ID

AUX1 ON

RESET

ACK

NEXT

PREV

S-CTL ID

STOP

PAUSE

CAM MENU ON

CAM MENU OFF

TOUR

SEQ

GROUP

SEQ

MONITOR

LOCK

OSD

ALARM

DISARM

ALL RESET

OPE ID

GROUP
PRESET

LOG OUT

F1

F2

GEN

WIPER

AUX2 OFF

MON STATUS

AUX2 ON

ALL

SHIFT

CLEAR

(ESC)

DEF OFF

DEF ON

CAMERA

(ENTER)

AUTO

PAN

FOCUS

FAR

NEAR

AUTO FOCUS

ZOOM

DOWN

UP

R

L

TELE

WIDE

Advertising