Transmission from the computer, Responses from the projector – Panasonic PT-DW5000 User Manual

Page 9

Advertising
background image

Transmission from the computer

(Used Only for PT-D10000/DW10000)

Transmission from the computer begins with STX, then the ID, command, and ETX are sent in this order.

When self-diagnosis result operation in the PT-D10000/DW10000, read commands of C1 and C2 command is necessary.
A command is binary 4 byte command.

STX

Start

0x02

ID

ID

0x00 ~ 0x40

C1

Command

0xfe

C2

Command

0xfe

ETX

End

0x03

ID:

ID ALL=0x00, ID1=0x01, ID2=0x02, ID3=0x03, ID4=0x04, ... ,ID63=0x3f, ID64=0x40

Projector default setting is ID ALL.

Responses from the projector

(Used Only for PT-D10000/DW10000)

STX

Start

0x02

ID

ID

0x00 ~ 0x40

C1

Command

0xfe

bit127

P1

P2

P3

P14

P15

P16

C2

Command

0xfe

ETX

End

0x03

Responses are binary 21 byte command.
Self-diagnosis results are 16 byte (128bit) command.

bit0

Self-diagnosis information 16 bytes

(128 bits)

9

Advertising