Port Address

Interrupt

LPT1 0x378 IRQ7
LPT2 0x278 IRQ5
LPT3 0x3BC IRQ5/7

4.2.2

PCAN-View for DOS

The program PCAN-View for DOS enclosed in the package is a CAN

monitor that supports various SJA1000/82C200 based PC hardware
extensions by PEAK-System. It is able to transmit and receive CAN

messages. As software with basic features it represents the Light
version of CANMON for DOS. With PCAN-View for DOS you can

examine existing nets and set up new ones.

Note: On PCs with processors with a clock frequency greater
than 400 MHz you should only use program versions > 3.0.

Program Initialization

1. Execute PCAN-View for DOS (file PCANVIEW.EXE).
2. Enter the port address and the interrupt of the parallel

interface.

3. Select the desired baud rate.

4. From the list of operating modes select one of those

beginning with "PEAK Dongle".
If your PC has an ECP interface and the corresponding

function is activated in the BIOS setup, you can use one of
the operating modes ending with "EPP". If you have

problems with these operating modes, select "PEAK Dongle-
CAN" instead.

5. By pressing [F10] the PCAN-Dongle is configured and linked

to the CAN.