OPERATION

Carburetion

Jetting Guidelines

Changes in altitude and temperature affect air density, which is the
amount of oxygen available for combustion. In low elevations and cold
temperatures, the air has more oxygen. In higher elevations and higher
temperatures, the air is less dense.

RMK carburetors are preset to operate at altitudes of 6000-8000 feet
(1800-2400 m) above sea level (see page 74 for more information). Car-
buretors must be re-calibrated if the snowmobile is operated outside this
production temperature and/or altitude range. The main jet installed in
production is not correct for all altitudes and/or temperatures.

NOTE: It’s the owner’s responsibility to ensure that the correct jets are

installed in the machine for a geographical area. Be very care-

ful when jetting down in warm weather. As the weather turns

colder it will be necessary to re-jet upward to prevent engine

damage. When selecting the proper main jet always use the

lowest elevation and temperature that is likely to be encoun-

tered.

CAUTION

A main jet that’s too small will cause a lean operating condition and may

cause serious engine damage. Jet the carburetors carefully for elevation and

temperature according to the jetting charts. Refer to the specifications sec-

tion beginning on page 106.