Troubleshooting related messages – Planar PR Line PR9020 User Manual

Page 68

Advertising
background image

66

Troubleshooting

Troubleshooting

Related messages

When the unit's power is on, messages such as those shown below may be

displayed. When any such message is displayed on the screen, please follow the

instructions described below. If the same message is displayed after the remedy,

or if a message other than the following appears, please contact your dealer or

service company.

Although these messages will be automatically disappeared around several

minutes, it will be reappeared every time the power is turned on.

Message

Description

There is no input signal.

Please confirm the signal input connection, and the status

of the signal source.

The horizontal or vertical frequency of the input signal

is not within the specified range.

Please confirm the specs for your projector or the signal

source specs.

The internal temperature is rising.

Please turn the power off, and allow the projector to cool

down at least 20 minutes. After having confirmed the

following items, please turn the power ON again.

• Is there blockage of the air passage aperture?

• Is the air filter dirty?

• Does the peripheral temperature exceed 35°C?

If the same indication is displayed after the remedy, please set

FAN SPEED of the SERVICE item in the OPTION menu to HIGH.

A note of precaution when cleaning the air filter.

Please immediately turn the power off, and clean or change

the air filter referring to the “Air filter” section of this manual

(62). After you have cleaned or changed the air filter,

please be sure to reset the filter timer (25, 63).