Techncial specifications, Installing a replacement power supply, Technical specifications – Paradyne 496-15149 User Manual

Page 2

Advertising
background image

2

Technical Specifications

Specification

Criteria

Rated Voltage (nominal)

100–250 Vac, 50/60 Hz

Rated Current

1.0 Amps

Operating Voltage Range (limits)

90–265 Vac 47–63 Hz

Power Consumption (typical)

120 Vac 29.7 watts 452 mA

230 Vac 29.9 watts 270 mA

Result: 102 Btu per hour

Installing a Replacement Power Supply

Install a replacement power supply using the following instructions.

!

WARNING:

Before you remove the power supply module, you

must unplug the power

cord from the power receptacle and from the rear of the housing before
attempting to remove the module.

1. Unplug the power cord from the power receptacle and from the rear of the housing.

2. Remove the front bezel by depressing the latch at the top of the housing and lifting

the bezel out of the two slots in the bottom of the housing.

496-15123

Advertising