Tube

Discharge

Suction Tube

Process or

4 holes

19mm (0.75") DIA

(3.46")

88mm

F

B

A

C

D

E

12.2mm (0.48")

(3.46")

88mm

(4.92")

125mm

(5.18")

131.6mm

(4.00")

101.6mm

(3.50")

89mm

205.1mm (8.07")

165.1mm (6.50")

(2.13")

54mm

(3.50")

84mm

Process or

Suction Tube

184mm DIA

(7.24")

Current Relay

M

C

S

~

1

2

3

Starting
Capacitor

Compressor

Motor

M

S

1

2

C.S.I.R.

Dimensions*

mm

inches

A . . . . . . . . . . . . . . . . . . . . . 208.6 . . . . . . . . . . . . . . . . . . . 8.21
B . . . . . . . . . . . . . . . . . . . . . 92.8 . . . . . . . . . . . . . . . . . . . . 3.65
C . . . . . . . . . . . . . . . . . . . . . 115.8 . . . . . . . . . . . . . . . . . . . 4.56
D . . . . . . . . . . . . . . . . . . . . . 77.0 . . . . . . . . . . . . . . . . . . . . 3.03
E . . . . . . . . . . . . . . . . . . . . . 62.2 . . . . . . . . . . . . . . . . . . . . 2.45
F . . . . . . . . . . . . . . . . . . . . . 77.0 . . . . . . . . . . . . . . . . . . . . 3.03

* All dimensions are for reference only

Tubes

Tube O.D.

Wall

Material

Suction . . . . . . . . . . 0.39 in. / 10 mm

0.035 in. / 0.9 mm

Copper

Process . . . . . . . . . 0.39 in. / 10 mm

0.035 in. / 0.9 mm

Copper

Discharge . . . . . . . . 0.33 in. / 8.3 mm

0.035 in. / 0.9 mm

Copper

U.L. File # . . . . . . . . . SA 4615
C.S.A. File #’s . . . . . . LR - 34080

LR - 36593

LR - 100738

General Data Oil Charge . . 250 cc ± 5 cc / 15.3 cu.in. ± 0.3 cu.in.

Net Weight With Oil . . . . . . . . . . . . 21.4 lbs, 9.7 kg

Approved Oils . . . . . . . . . . . . . . . . . . FREOL

α

22

Residual Moisture . . . . . . . . . . . . . . . 120 mg max.

Impurities . . . . . . . . . . . . . . . . . . . . . . 10 mg max.

Displacement . . . . . . . . . . . 9.07 cc. / 0.553 cu. in.

Panasonic Industrial Company

Refrigeration Products Department

Tel: 201 - 392 - 4249

Fax: 201 - 392 - 4315

Rev#1-5/9

This document sets forth certain operational parameters and conditions for
operation of this product. If this product is operated outside of the parameters
and conditions stated herein, buyer assumes sole and full responsibility and
shall indemnify seller with respect to all product failures and all consequences
thereof. Operation of the product outside of the parameters and conditions
specified herein shall serve to invalidate all seller warranties, if any, with respect
to the product. This document is for reference only. For specifications, please
contact Panasonic’s engineering department.

MATSUSHITA

Compressor

Single Phase

115 V

MODEL# QA91K22CAU6 (80µF Start Cap.)

R-134a

60 Hz