Problem cause correction – Porter-Cable D25804-025-1 User Manual

Page 17

Advertising
background image

17- ENG

D25804

Water leaking
at pump

Water leaking
at gun/wand
connection

No or low
pressure
(after period of
normal use)

PROBLEM

CAUSE

CORRECTION

Wand not in low pressure.

See How to Use Wand paragraph
in the Operation Section.

Chemical screen not in chemical

Clean filter.

Chemical too thick.

Dilute chemical. Chemical should
be the same consistency as
water.

Pressure hose is too long

Lengthen water supply hose
instead of pressure hose.

Chemical build up in chemical
injector.

Have parts cleaned or replaced
by AWSC.

Worn seal or packing

Have replaced by AWSC.

Worn or obstructed valves.

Have replaced by AWSC.

Worn unloader piston.

Have replaced by AWSC.

Worn E-Z start valve.

Check and replace.

Loose hose connection.

Loose connections.

Tighten.

Piston packings worn.

Have replaced by AWSC.

Worn or broken o-rings.

Have replaced by AWSC.

Pump head or tubes damaged
from freezing.

Have replaced by AWSC.

Will not draw
chemicals

Insure end of chemical hose is
fully submerged into chemical.

Chemical filter clogged.

Worn or broken o-ring.

Tighten.

Have replaced by AWSC.

Oil leaking at
pump

Oil seals worn.

Have replaced by AWSC

Loose drain plug.

Worn drain plug, o-ring

Worn fill plug o-ring.

Pump overfilled.

Incorrect oil used.

Vent plug is clogged.

Tighten.

Check and replace.

Check and replace.

Check for correct amount.

Drain and fill with correct amount
and type of oil.

Clean vent plug; blow air through it
to remove any blockage. If prob-
lem persists, replace plug.