Lc2h, Input method, Standard type – Panasonic LC2H User Manual

Page 7: Pc board pattern (bottom view)

Advertising
background image

LC2H

Input method

1. Standard type

Notes) 1. When using contact input, since current flow is small from terminals 1 and 3 on the panel mounting type and terminals e to t and S to F on the PC board

mounting type, please use relays and switches with high contact reliability.

2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage Q 50 V, leakage current < 1 µA)

Notes) 1. 2 and 4. (The input and reset circuits are functionally insulated.)

2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input

terminal, can cause damage to the internal elements.

Non-voltage input type

Panel mounting type

PC board mounting type

Contact input

Transistor input

Contact input

Transistor input

NPN transistor

NPN transistor

Voltage input type

Free voltage input type

Contact input

Transistor input

NPN transistor

PNP transistor

2. PC board mounting type
• External dimensions

• Terminal layout and wiring diagrams

General tolerance:

±1.0

±.039

mm

inch

PC board pattern (BOTTOM VIEW)

General tolerance:

±0.1

±.004

Note: The AXS212811K is recommended as a compatible connection socket.

LC2H

COUNTER

33.02

±0.3

1.300

±.012

43.4

1.709

17.3

.681

DIP switch

× 8

19

.748

15.24

±0.3

.600

±.012

3.3

±0.3

.130

±.012

5.08

±0.3

.200

±.012

0.5

±0.3

.020

±.012

0.3

±0.1

.012

±.004

5.08

±0.3

.200

±.012

0.6

±0.1

.024

±.004

Q-E, }-w, e-t and S-F are connected internally.
An external power supply is required.

Reset input

Count input

15 17

26 28

14 12

3

1

15.24

.600

33.02

1.300

1.9

.075

1.9

.075

5.19

.204

2.54

.100

2.54

.100

8-0.8 dia.

8-.031 dia.

5.08

.200

5.08

.200

5.19

.204

Mounting area

Connection sockets
28 pin DIP terminal

1

2

3

4

Reset

input

Count

input

(W and R are connected internally.)

1

2

3

4

0V

0V

(W and R are connected internally.)

Reset

input

Count

input

Reset

input

Count

input

3V DC

15

17

14

12

26

28

3

1

Reset

input

Count

input

3V DC

15

17

14

12

26

28

3

1

Reset

input

Count

input

1

2

3

4

1

2

3

4

Reset

input

Count

input

+V

+V

Reset

input

Count

input

1

2

3

4

+V

+V

1

2

3

4

or

or

or

Reset input

Count input

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: [email protected]