Perlick Z2148EMU User Manual

Part no

Advertising
background image

Problem:

Beer flow is slower with Universal Empty Keg Sensor
than with standard Perlick coupler.

Probable Cause:

Beer Flow Control Handle is in CLEAN position.

Solution:

Slowly turn Beer Flow Control Handle to ON position.

Problem:

Beer does not flow after keg is tapped.

Probable Cause:

Universal Empty Keg Sensor has locked up.

Solution:

Turn Beer Flow Control Handle to OFF position.
Wait two or three seconds than slowly turn Beer Flow
Control Handle to ON position.

Probable Cause:

Beer Flow Control Handle is OFF.

Solution:

Slowly turn Beer Flow Control Handle to ON position.

Probable Cause:

Universal Empty Keg Sensor is dirty.

Solution:

Clean Universal Empty Keg Sensor.

Probable Cause:

Out of gas.

Solution:

Reestablish gas flow.

Problem:

Excessive foam.

Probable Cause:

Beer temperature too high. Excessive beer flow rate. Beer
is over-carbonated

Solution:

These problems are not caused by the Universal Empty
Keg Sensor. Follow established procedures to correct
the problem.

* U.S. Patent #5,630,411

Form Z2148EMU

08.20.04

8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060
Fax 414-353-7069 • Toll Free 800-558-5592 • E-Mail: [email protected] • www.Perlick.com

INSTALLATION AND OPERATING INSTRUCTIONS

UNIVERSAL EMPTY KEG SENSOR

The Perlick Universal Empty

Keg Sensor shuts off the flow

of beer when the keg empties.

With the line full of beer, the

foaming and resulting beer

waste from changing kegs is

eliminated.

Part No.

43739

No. 43739

Universal Empty

Keg Sensor

IMPORTANT!

To ensure your complete satisfaction, please read these instructions

before using Perlick’s Universal Empty Keg Sensor.

Troubleshooting