Operating your heater – Procom ML300TBA User Manual

Page 12

Advertising
background image

1 2

OPERATING YOUR HEATER

NON-THERMOSTAT MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow

these instructions exactly, a fire or
explosion may result causing
property damage, personal injury or
loss of life.

A. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas.
Be sure to smell next to the floor
because some gas is heavier than
air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any

appliance.

Do not touch any electric

switch; do not use any phone

in your building.

Immediately call your gas

supplier from a neighbor’s
p h o n e . F o l l o w t h e g a s

supplier’s instructions.

if you cannot reach your gas

supplier, call the fire

department.

C. Use only your hand to push in
or turn the gas control knob.
Never use tools. If the knob will
not push in or turn by hand, don’t
try to repair it , call a qualified
service technician or gas supplier.
Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any
part has been under water.
Immediately call a qualified service
t e c h n i c i a n t o i n s p e c t t h e
appliance and to replace any part of
the control system and any gas
control which has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety
information, on the side of
heater.
2. Make sure equipment shutoff
valve is fully open.
3. Push in control knob slightly

and turn clockwise

to the

OFF position (see Figure 19).
4. Wait five minutes to clear out

any gas. Then smell for gas,
including near the floor. If you
smell gas.STOP! Follow

"

B

"

in the

safety information on the side of

heater. If you can’t smell gas, go

to the next step.

5. Push in and turn control knob

counterclockwise

to PILOT

position. Press in control knob

for five(5) seconds.
Note: You may be running

this heater for the first time
after hooking up to gas supply.
If so, you may need to press
in control knob for 30 seconds.
This will allow air to bleed from

the gas system.

TO TURN OFF

GAS TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to the
appliance if service is to
be performed.

Shutting Off Burner Only (pilot
stays lit )
Slightly press in control, turn
control knob clockwise

to the

PILOT position.

Figure 19 - Control Knob in The
OFF Position

Figure 20 - Pilot

6. With control knob pressed in,

push down and release the
ignitor button. This will light
pilot. if needed, keep pressing
ignitor button until pilot lights.

7. Keep control knob depressed

for ten(10) seconds after
lighting pilot. If pilot goes out,
repeat steps 5,6 and 7.

8. To select the desired heating

level, partially press down the
control knob slightly and rotate
counterclockwise . Release
the downward pressure on the
knob while continuing to turn
until the knob locks at the
desired setting position. Do not
o p e r a t e b e t w e e n l o c k e d
positions.

1. Remove lower front panel (see

Figure 7 page 7)

2. Follow steps 1 through 5

under Lighting Instructions .

3. With control knob pressed

in, strike match. Hold match to

pilot until pilot lights.
4. Keep control knob pressed in

for 30 seconds after lighting
pilot . After 30 seconds, release

control knob. Follow step 8 under

Lighting Instructions.

5. Replace lower front panel.

MANUAL LIGHTING

PROCEDURE

Advertising
This manual is related to the following products: