3.1.1 Switch Set S1

The configuration switches on S1 set clocking, rate adaptation,

loopback enable, data invert, and interface (see also Switch S2). The
default settings are summarized in table below.

Switch S1-1: Terminal Interface (Works in Conjunction with

Switch S2)

Set Switch S1-1 (as well as S2-1 and S2-2)to determine whether

the signals passed between the Model 2703 and the terminal device
will follow the EIA-530 (RS-422), CCITT X.21 or CCITT V.35 standard.
If S2-1 and S2-2 are set for “EIA-530/X.21,” then the setting for S1-1
determines which of those two interfaces is selected. Note: If S2-1
and S2-2 are set for “V.35,” switch S1-1 must be set to “off.”
Regardless of the pin-out standard chosen, the physical connector is a
female UD-26.

S1-1

Setting

Off

V.35 Interface

On

X.21/EIA-530 (RS-422) Interface

S1-2 and S1-3:

Reserved for Future Use

5

S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

X.21/V.35

Off

V.35

S1-2

Reserved

Off

S1-3

Reserved

Off

S1-4

Rate Adaptation

Off

S1-5

Rate Adaptation

Off

S1-6

Data Inversion

Off

Not Inverted

S1-7

Clock Master/Slave

Off

Slave

S1-8

Test Enable

Off

Front Panel

}

2.048 Mbps

Switches S1-4 and S1-5: Rate Adaptation

Set Switches S1-4 and S1-5 together to allow the Model 2703 to

adapt to terminal devices that run at data rates less than 2.048 Mbps
(The network rate remains 2.048 Mbps regardless of the terminal rate
adaptation setting). The setting you select must match the data rate of
your terminal device.

S1-4

S1-5

Setting

Off

Off

2.048 Mbps

On

Off

1.024 Mbps*

Off On

512

kbps*

On

On

256 kbps*

Switch S1-6: Data Inversion

Set Switch S1-6 to determine whether or not the data stream from

the local DTE is inverted within the Model 2703 before being passed to
the G.703 network. You may need to invert the data stream when you
use the Model 2703 with an imbedded G.703 device that inverts the
data on the remote end. Normally, data inversion is not necessary.

S1-6

Setting

On

Data inverted

Off

Data not inverted

Switch S1-7: Master/Slave Clock

Set Switch S1-7 to allow the Model 2703 to provide the master

clock, or recover the clock from the G.703 network.

S1-7

Setting

On

Model 2703 is master

Off

Model 2703 is slave, (clock is recovered
from the network)

6

*NOTE: Revision C. Firmware (or newer, Implemented 6/19/98)
has been adopted to correct signal polarity at 1.024 Mbps, 512
kbps, and 256kbps. To operate Revision. C Firmware units with
Revision B. (or older) units at one of these sub-rates, you must
invert the data (Switch S1-6 On. See Below) (Firmware revision
level is printed on the label on the bottom of the unit).