Alarm functions, When an alarm arises – Pantech WV-NW474S User Manual

Page 48

Advertising
background image

-48-

When an alarm sounds, the camera performs output
functions depending on the setup.

Inputs:

• The alarm sensor connected to the ALARM IN termi-

nal on the camera

• The built-in VMD (Video Motion Detector) that

detects a motion in video by monitoring the speci-
fied area

Outputs:

• “Alarm” display appears in the upper center of the

main page.

• The picture files as an alarm sounds are stored in

the camera.

• An E-mail notifies the specified addresses of the

alarm activation with or without a picture file.

• The stored picture files are sent to the FTP server.
• The ALARM OUT terminal on the camera becomes

active.

• The notice of an alarm activation is sent to the server

specified in Panasonic Protocol Setup, using the
Panasonic's original protocol.

When an Alarm Arises

• “Alarm” display appears in the upper right corner of

the main page. The alarm status display may delay
for a maximum of half a minute due to its refresh
cycle.

• The pictures as an alarm sounds are stored in the

memories of the camera.
The total storage number of the pictures depends
on three factors: pixel numbers, picture quality, and
the number of pre-alarm storage. The existing oldest
data will be replaced with new picture data when
the data volume exceeds over the memory capacity.
The tables below give guidelines of the available
picture numbers for the post-alarm storage.

When pre-alarm file is set to 20

ALARM FUNCTIONS

Pixel

numbers

640 x 480

640 x 240

320 x 240

Super Fine

113

247

514

160 x 120

514

Picture quality

Fine

165

351

722

722

Normal

210

440

901

901

LOW

242

451

922

922

When pre-alarm file is set to none

Pixel

numbers

640 x 480

640 x 240

320 x 240

Super Fine

133

267

534

160 x 120

534

Fine

185

371

742

742

Normal

230

460

921

921

LOW

262

471

942

942

Picture quality