Installation and Operating Instructions

2

PARTYMASTER DISPENSER

Form No. Z2022A
2/25/98

Connecting the Regulator to the CO

2

Cylinder

1.

Remove blue plug from regulator fitting.
(Note: Do not remove the carbonic washer.)

2.

Screw regulator onto gas cylinder valve. Tighten
with wrench until vertically straight. Be sure that
shut-off valve (black lever) on regulator is in
OFF (horizontal) position.

3.

Place a screw clamp over end of red air line and push
onto regulator tailpiece. Tighten clamp with a screwdriver.

Adjusting CO

2

Gas Flow

1. Turn regulator adjusting screw counterclockwise until it turns freely.
2. Turn hand valve counterclockwise on CO

2

cylinder

to the fully open position.

3. Turn regulator adjusting screw clockwise until desired

pressure is reached (approx. 12-15 lbs.). Tighten stop nut on adjusting screw.

4. Open shut-off valve on bottom of regulator.

CO

2

Leak Test

Dilute a small amount of liquid dishwashing soap and rub the soapy
mixture around each connection. If bubbles appear, tighten connection.

Replacing CO

2

Gas Cylinder

1. Turn the CO

2

hand valve clockwise until seated and close shut-off valve on regulator.

2. Unscrew regulator from cylinder fitting.
3. Replace carbonic washer (Part No. 157F2P), if needed and reattach regulator to filled cylinder.
4. Turn CO

2

hand valve counterclockwise until fully open. Turn regulator shut-off valve

to open position.

5. Adjust CO

2

gas flow as required, turning clockwise for higher pressure.

Proper CO

2

Handling

Always...

Connect a regulator (reducing valve) to a CO

2

cylinder.

Secure cylinder in upright position whether in storage or in use.

Keep cylinder away from heat. Rupture disc vents at 122

o

F. maximum.

Ventilate room after high pressure gas leakage.

Check the last DOT test date on cylinder neck before filling. If more than five

years old,

the cylinder must be retested to DOT specifications.

Be sure CO

2

cylinder outlet fitting is free of dust or dirt before attaching regulator.

Store CO

2

cylinder and regulator assembly upright.

Allow only properly trained and experienced personnel to handle high pressure gas.

Never...

Connect cylinder directly to a keg without a regulator (reducing valve).

Drop or throw regulator or CO2 cylinder.

Transport CO

2

cylinder in a closed vehicle.

Apply oil to a regulator.

Shut off CO

2

cylinder when not in use. You will not save gas by doing so!

Allow untrained, inexperienced personnel to handle high pressure gas.
Failure to heed this warning could result in personal injury or death.

CO

2

Gas

Drum

Shut Off Valve

(Black Lever in

Closed Position)

Hand

Valve

Cover for

Adjusting Broach

CO

2

Pressure

Gauge

Regulator

Fitting

WARNING/SAFETY

INSTRUCTIONS

Beverage systems
pressurized with carbon
dioxide or nitrogen must
be equipped with two
safety relief valves; one
at the cylinder regulator
and the other in the gas
line upstream on the
product tanks.