Primera Technology AP362 User Manual

Page 13

Advertising
background image

AP360/362 Label Applicator 13

4. Press the Foot Switch to apply the labels. Both labels will be applied

without pressing the Foot Switch again.

To set a value for another memory location, repeat this procedure.

Note:

The distance values are approximate. Adjusting the position of the

Container Idler Roller will affect the actual distance between the labels on the container.

C. Calculate distances for two-label mode.

If you intend to apply two labels to the same container you will typically want to center the

second label so that you have the same distance between each label on both sides. Use this

formula to calculate the proper distance setting (see Section 4B).

1. First Calculate the circumference of your container.

diameter of container x Pi = circumference

2. Now subtract the width of both front and back labels from the circumference and

divide by two.

(circumference - width of front label - width of back label) / 2

3. Subtract the distance between the labels on the liner (the distance between the labels while they

are still attached to the roll) from the value received in step 2.

Example:

If your bottle is 3 inches in diameter, your front label is 4 inches wide, your back label is

2.5 inches wide, and the distance between the labels on the liner is .12, the distance value

to enter would be 1.34 inches.

3 x

π

= 9.42

(9.42 - 4 - 2.5)/2 = 1.46 - 0.12 = 1.34

Note:

The value given by this formula is a good starting point. Some

adjustments may be needed depending on the particular container

and the Container Idler Roller position.

D. Count labels (AP362 Only)

By default the AP362 Label Applicator will begin to count labels. This

count will be displayed on the LCD. If you press any of the buttons on

the control panel the label count will momentarily disappear. It will

reappear ten seconds after the button is pressed. (Figure 4.3.)

Press and hold the Recall/Reset Button for five seconds to reset the label

counter to zero.

Note:

The label counter will reset to zero if power is switched off.

Mode

Recall/

Reset

+

-

Figure 4-3.

Advertising