To set up the lighting system, first mount and secure all light heads to suitable
stands. The stand adapter allows the light head to be mounted on a stand with a 3/8”
to 5/8” post. Be sure to use a stand that is stable and will not tip easily.

The light heads are shipped with the modeling lamp and flashtube not installed.
While installing the modeling lamp and flashtube (with glove or clean cloth to
protect the hand) be certain they are properly inserted and tight to avoid arcing and
failure of the socket contacts during operation. Do not touch the glass tubes with
bare hands, as normal body oils will shorten the bulb’s life. Always use a clean
cloth or wear gloves to protect your hand from glass breakage and heat.

The 7 ½ inch reflector is attached to the PA8 by the “quick-change” mechanism.
Three tabs on the unit grip the ring on the reflector. Finger levers located on the top
of the unit control two of these tabs. To mount the reflector, squeeze the finger
levers towards each other and tilt the reflector past the stationary top-tab, then past
the two tabs that are controlled with the levers. Release the finger levers and make
sure all three tabs are securing the reflector (see illustration below.) All accessory
reflectors and soft boxes are designed for use with this “quick-change” system or
onto this 7-½ inch reflector

Squeeze levers to mount
reflector in locked position.

Punch out hole for Professional plug-in
umbrella rod. flashtube.

With power supply’s power switch OFF, attach the line cord to the power-
input connector, located on the back of the PhotoMaster, and connect it to a
grounded wall outlet. Turn the power switch ON. The READY light will
light when the unit has charged to the power level set by the FLASH power
control.