Connecting intellichlor to an suntouch system – Pentair IC20 User Manual

Page 39

Advertising
background image

31

IntelliChlor Electronic Chlorine Generator Installation and User’s Guide

Connecting IntelliChlor to an SunTouch System

To connect the four wire cable from the IntelliChlor Power Center (see page 28) to the motherboard located in
the SunTouch Power Center:

WARNING - Switch OFF main system power to the SunTouch Power Center before making any connec-

tions.

To access the SunTouch Power Center electronics compartment:

1. Unlatch the front door of the SunTouch Power Center, and open the door.

2. Loosen the retaining screw on front panel. Open the hinged front panel to access the electronics

compartment.

3. Route the four conductor cable up through the Power Center grommet opening located on the left

side, and up through the low voltage raceway to the motherboard.

4. Strip back the cable conductors ¼ in. Insert the wires into the screw terminals (provided in the kit).

Secure the wires with the screws. Make sure to match the color coding of the wires; Red = +15,
Yellow = +DT, Green = -DT, and GND = Black.

5. Insert the connector on the COM-PORT (J11) screw terminal on the motherboard.

6. When the connection is completed, close the control panel and secure it with the retaining screw.

7. Close the front door. Fasten the spring latch.

V

AL
VE A

CTU

A

T

ORS

COM PORT

INT

AKE

RETURN

SOL

AR

A

UX 3

PUMP

A

UX 2

A

UX 1

VL
V A

VL
V B

VL
V C

ONL

Y

SOL

AR

CLNR

GAS
HEATER

RESET

SunTouch motherboard