Pitco Frialator Self-Cleaning Burner System User Manual

Page 7

Advertising
background image

5 L80-029 Rev 5 10/07

NOTE: CE approved models will have a pressure test
fitting in this location. For CE approved models, remove
this pressure test fitting using a 7/16” (12 mm) wrench.
Using a 3/16” (5 mm) hex key, remove the plug from the
auxiliary pressure tap on the manifold inlet and replace
it with pressure tap fitting that you removed from the
TOP (Outlet side) of the valve. Use teflon tape or apply
pipe joint compound on the threads of the fitting to
ensure a gas-tight seal.

b. Remove the straight 1/8” NPT X ¼” compression fitting

from the U tube end of the SCBS Valve Assembly
provided with the kit and, with a 7/16” wrench, install it
into the recently vacated pressure test port on the TOP
(Outlet Side) of the valve. Use teflon tape or apply pipe
joint compound on the threads of the fitting to ensure a
gas-tight seal.
NOTE: The threads on this fitting (1/8’ NPT and ¼”
compression) are not interchangeable. Be sure to
install the NPT side of this fitting into the gas valve.
Failure to complete this step correctly could damage
the threads of both the fitting and the pressure test
port, and may result in gas leakage at this joint.

c. Remove the 1/8” NPT X 90° ¼” compression fitting from

the other end of the SCBS Valve Assembly provided
with the kit and install the orifice tip, also provided in the
kit, on to the NPT end of the fitting. Insert the orifice end
of this assembly into the runner tube installed previously
in this procedure. NOTE: Check the orifice against the
parts list included in these instructions to insure that it is
the correct size for the gas type of your appliance.

d. Mount the SCBS Valve Assembly into the appliance by

loosely attaching the U tube end of the assembly onto
the straight fitting that you installed into the TOP (Outlet
Side) of the gas valve in step b.

Advertising