SECURE RACKING

If Secure Racked units are installed in a closed or multi-unit rack assembly, they may require further

evaluation by Certification Agencies. The following items must be considered.

1. The ambient within the rack may be greater than room ambient. Installation should be such

that the amount of air flow required for safe operation is not compromised. The maximum

temperature for the equipment in this environment is 45°C. Consideration should be given to the

maximum rated ambient.

2. Installation should be such that a hazardous stability condition is not achieved due to

uneven loading.

INPUT SUPPLY

Check nameplate ratings to assure there is no overloading of supply circuits that could have an effect

on overcurrent protection and supply wiring.

GROUNDING

Reliable earthing of this equipment must be maintained. Particular attention should be given

to supply connections when connecting to power strips, rather than direct connections to the branch

circuit.

No Serviceable Parts Inside; Authorized Service Personnel Only

Do not attempt to repair or service this device yourself. Internal components must be serviced by

authorized personnel only.

• Shock Hazard - Do Not Enter

Disconnect Power

If any of the following events are noted, immediately disconnect the unit from the outlet and contact

qualified service personnel:

1. If the power cord becomes frayed or damaged.

2. If liquid has been spilled into the device or if the device has been exposed to rain or water.

Two Power Supply Cables

Note that this unit includes two separate power circuits, with a power supply cable for each

circuit. Before attempting to service or remove this unit, please make certain that both power cables
are disconnected.