Storage – Porter-Cable 1000002853 User Manual

Page 15

Advertising
background image

15 - ENG

1000002853

TO REPLACE REGULATOR

1. Release all air pressure from air

tank. See "To Drain Tank" in the
Maintenance section.

2. Unplug

unit.

3. Remove the console cover.
4. Using an adjustable wrench or

specified wrench remove the gauges,
quick connect, and safety valve from
the regulator.

5. Remove the hose by removing the

hose clamp. NOTE: The hose clamp is not reusable. You must purchase a
new hose clamp, see the Parts List or purchase a standard hose clamp at a
local hardware store.

6. Remove pump mounting screws securing pump (one on each side).
7. Carefully slide pump from brackets and out of the way.
8. Using an adjustable wrench remove the regulator manifold.
9. Apply pipe sealant to new regulator manifold and assemble, tighten with

wrench.

10. Reapply pipe sealant to gauges, quick connect, and safety valve.
11. Reassemble all components in reverse order of removal. Make sure to orient

gauges to read correctly and use wrenches to tighten all components.

Regulator

Hose
Clamp

Pump Mounting Screw

Pump shown

moved out of
the way

STORAGE

Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform

scheduled maintenance as necessary.

2. Set the On/Off switch to "Off" and unplug unit.
3. Turn the regulator counterclockwise and set the outlet pressure to zero.
4. Remove the air tool or accessory.
5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure

is approximately 20 PSI. Release safety valve ring.

6. Drain water from air tank by opening drain valve on bottom of tank.

Quick
Connect

Safety Valve

Regulator

Gauges

Console Cover

Advertising