30 x – Panasonic WV-NW502SK User Manual

Page 30

Advertising
background image

30

x

Connect an external amplifier-embedded speaker to the audio output connector
(for use of the audio transmission function).

Connect a stereo mini plug (ø3.5 mm) (monaural output).
• Recommended cable length: 10 m {33 ft} or less

c

Connect the alarm input/output cable.

Rating of ALARM IN/OUT

<Ratings>

• ALARM OUT

AUX OUT / EXPOSURE OUT
Output specification: Open collector output (maximum applied voltage: DC 20 V)
Open: DC 4 - 5 V by internal pull-up
Close: Output voltage 1 V DC or less (50 mA or less)

• ALARM IN1 / DAY NIGHT IN

ALARM IN2
ALARM IN3
Input specification:

Non-voltage make contact input
(DC 4 - 5 V internal pull-up)

OFF: Open or DC 4 - 5 V
ON: Make contact with GND (required drive current: 1 mA or more)

Note:

• Check if rating of an external device such as a sensor is applicable to the rating of this

product by referring to the provided operating instructions.

4P alarm cable (accessory) pin configuration

1

Black

GND

2

Gray

ALARM IN3/AUX OUT/EXPOSURE OUT
(Alarm input terminal 3/AUX output terminal/exposure timing output terminal)

3

Red

ALARM IN2/ALARM OUT
(Alarm input terminal 2/alarm output terminal)

4

Green

ALARM IN1/DAY NIGHT IN
(Alarm input terminal 1/color-BW selection input terminal)

Advertising
This manual is related to the following products: