Patton electronic 1090 User Manual

Page 5

Advertising
background image

S1-8: V.54 Enable / Disable

The setting for switch S1-8 determines whether the Model 1090 will

respond when it receives the V.54 sequence. If you suspect the Model
1090 may be getting tricked into the loopback test by false detection of
user data, you can try setting this to “Disable.”

S1-8

Setting

On

Disabled

Off

Enabled

SWITCH SET S2

The settings for DIP switches S2-1 through S2-4 determine the

synchronous data rate of the Model 1090. All possible settings
(including the default) are shown below:

S2-1

S2-2

S2-3

S2-4

Setting

Off

Off

Off

On

48 kbps

Off

Off

On

Off

56 kbps

Off

Off

On

On

*64 kbps

Off

On

Off

Off

72 kbps

Off

On

Off

On

80 kbps

Off

On

On

Off

112 kbps

Off

On

On

On

128 kbps

On

Off

Off

Off

144 kbps

On

Off

Off

On

160 kbps

* Default Setting

7

8

4.0 INSTALLATION

Once the Model 1090 is properly configured, it is ready to connect

to the twisted pair interface, to the serial port, and to the power source.
This section tells you how to make these connections.

4.1 CONNECTION TO THE TWISTED PAIR INTERFACE

The Model 1090 supports communication between two terminal

devices at distances to 11 miles and data rates to 160 kbps. There are
two essential requirements for installing the Model 1090:

1.

These units work in pairs. Therefore, you must have one
Model 1090 (or a compatible model) at each end of a two
twisted pair interface.

2.

To function properly, the Model 1090 needs two twisted pairs
of metallic wire. These twisted pairs must be
unconditioned, dry, metallic wire, between 19 and 26 AWG
(the higher number gauges may limit distance somewhat).
Standard dial-equalization equipment, or standard, flat
modular telephone type cable, are not acceptable.

4.1.1 TWISTED PAIR CONNECTION USING RJ-45

The Model 1090 uses a modular RJ-45 jack for twisted pair line
connection. The signal/pin relationships are shown below:

RJ-45

SIGNAL

1 ..........................XMT+
2 ..........................XMT-
3 ..........................N/C
4 ..........................GND*
5 ..........................GND*
6 ..........................N/C
7 ..........................RCV+
8 ..........................RCV-

*Connection to ground is optional

1
2
3
4
5
6
7
8

Advertising