Lk-t, Types and coil data (at 20 ° c 68 ° f ) dimensions, Reference data – Panasonic LK-T Relays User Manual

Page 2

Advertising
background image

LK-T

2

ds_61113_0004_en_lkt: 091008J

TYPES AND COIL DATA (at 20

°C

68

°F

)

DIMENSIONS

mm

inch

REFERENCE DATA

Part No.

Nominal voltage,

V DC

Pick-up voltage,

V DC (max.)

(Initial)

Drop-out

voltage,

V DC (min.)

(Initial)

Coil resistance,

Ω (±10%)

Nominal

operating

current, mA

(

±10%)

Nominal

operating power,

mW

Maximum

allowable

voltage, V DC

(at 20

°C

68

°F

)

LKT1aF-5V

5

(Initial) 3.5

(Initial) 0.5

100

50

250

6.5

LKT1aF-9V

9

(Initial) 6.3

(Initial) 0.9

324

27.8

250

11.7

LKT1aF-12V

12

(Initial) 8.4

(Initial) 1.2

576

20.8

250

15.6

LKT1aF-24V

24

(Initial) 16.8

(Initial) 2.4

2,304

10.4

250

31.2

4

0.5

1.65

Max. 25.0

Max. 11.0

0.3

0.5 dia.

20.0

16.5

0.4

Max. 24.0

7.5

1.0

.157

.020

.065

.984

.433

.012

.020 dia.

.787

.650

.016

.945

.295

.039

Dimension:

General tolerance

Max. 1mm

.039 inch

:

±0.1

±.004

1 to 3mm

.039 to .118 inch

:

±0.2

±.008

Min. 3mm

.118 inch

:

±0.3

±.012

PC board pattern (Bottom view)

Tolerance:

±0.1

±.004

Schematic (Bottom view)

2-0.9 dia.

2-1.3 dia.

16.5

7.5

20.0

2-.035 dia.

2-.051 dia.

.650

.295

.787

1. Max. switching power (AC resistive load)

2. Coil temperature rise

Sample: LKT1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 0 A, 5A

3. Ambient temperature characteristics and coil
applied voltage

100

10

1

5

0

10

100

Contact voltage, V

Contact current, A

80

0

0

5

10

15

20

25

30

100

120

20

°C 5A

20

°C 0A

70

°C 5A

70

°C 0A

Temperature rise,

°C

Coil applied voltage, %V

0

500

400

300

200

100

0

10

20

30

40

50

60

70

80

Ambient temperature,

°C

Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 115

°C

Pick-up voltage

Coil & contact no carrying current

Coil applied voltage, %V

Carrying current: 5A

239

°F

)

4-(1). Electrical life test
(5 A 277 V AC, resistive load)

Sample: LKT1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20

°C

68

°F

Circuit:

Change of pick-up and drop-out voltage

Change of contact resistance

12V DC

Contact
welding
detection
and Mis-
contacting
detection
circuit

277V AC

0

0

2

4

6

8

10

12

5

10

Drop-out voltage

Pick-up voltage

Max.

Min.

x

Max.

Min.

x

No. of operations,

×10

4

Pick-up and drop-out voltage, V

0

0

5

10

15

20

25

30

35

40

45

50

10

5

Max.

Min.

x

No. of operations,

×10

4

Contact resistance, m