Caution, Save these instructions, Installing the cable and lens subassembly – Pentair Fiberworks Wide Angle Lens User Manual

Page 2

Advertising
background image

4/04/02

Instruction P/N 99293000

Rev B

Pentair Pool Products

1620 Hawkins Ave., Sanford, NC 27330 ~ (919) 774-4151

10951 West Los Angeles Ave., Moorpark, CA 93021 ~ (805) 523-2400

Installing the Cable and Lens Subassembly

(for preOptiFused and bulk cable applications)

Feed the AmerGlow cable through the conduit leaving one foot of extra cable at each end.

If using bulk cable, assemble the lens subassembly as shown in the figure below.

Terminate the cable using the OptiFusion process as described in the full instructions packed

with the Photon Generator or OptiFusion Termination Kit. Any other process may dramatically
reduce light output.

CAUTION

DO NOT use Optifusion gel on the wide angle lens. The gel will inhibit the light dispersion

capabilities of the lens and the lens will not perform as intended.

Make sure the lens o-ring and spacer o-ring (if applicable) are in position and the o-ring sealing

surface on the inner flange of the lens housing is clean.

Continue feeding the cable until the lens assembly is about ½” away from the seated position.

Place the lens retaining nut onto the lens and PUSH the lens into place.

Hand tighten the lens using the lens tightening tool until the o-ring is seated.

For Standard Gunite and Fiberglass lens housings (which do not use the spacer and spacer o-

ring), hand tighten the lens retaining nut ¼ turn past the seated o-ring position.

For Invisible Gunite and Vinyl Liner housings (which use the spacer and spacer o-ring) hand

tighten the lens retaining nut ½ turn past the seated o-ring position.

Save These Instructions

Lens retaining

nut

Standard

Lens

Lens o-ring

Seal nut

Seal nut o-ring

Compression nut

Grommet

Spacer with o-ring - use
with Invisible Gunite and
Vinyl Liner lens housings

FIBERworks lens housing
(Invisible Gunite shown)

1/16”

1”

Wide Angle

Lens

CAUTION

DO NOT over tighten lens retaining nut. Damage to lens assembly may result in

leakage of pool water into conduit.

Advertising