Auto filter cleaning, Auto, Air conditioner timer – Panasonic CS-XE12EKE User Manual

Page 7: Force cleaning

Advertising
background image

7

ENGLISH

AUTO FILTER CLEANING

Auto Filter Cleaning

AUTO

AUTO

• Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned

off using remote control).

• After the filter cleaning is completed, the air conditioner operation will remain off.

AIR CONDITIONER TIMER

AIR CONDITIONER TIMER

• Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned

off by the air conditioner timer).

• After the filter cleaning is completed, the air conditioner operation will remain off.

Filter Cleaning Indicator

FORCE CLEANING

FORCE CLEANING

• Once the air conditioner operation time exceeds 24 hours, the unit is forced to run filter cleaning.
• After the filter cleaning is completed, the air conditioner operation will resume automatically.

• The fi lter cleaning indicator light

will move to left or right when fi lter
cleaning is in progress.

• Filter cleaning in progress will be

cancelled if:

- Certain button on the remote

control are pressed.

- The air conditioner main unit’s

movable front panel is lifted up.

- There is a power failure.

Troubleshooting

● Timer indicator is blinking and error code H51 is

revealed on the display.

► The fi lter cleaning device is jammed because the fi lter is not installed

correctly.

► The fi lter cleaning device is malfunction.

● Timer indicator is blinking and error code H52 is

revealed on the display.

► The fi lter cleaning device is malfunction.
► Printed circuit board is malfunction.

Note :
• To reveal the error code, please refer to Product Overview’s troubleshooting-error code checking.
• The condition above does not affect the unit’s operation.
• In case of malfunction, please consult your nearest authorized dealer.