Switches s1-1 and s1-2: data rate – Patton electronic 1082/144 User Manual

Page 10

Advertising
background image

10

Note

When setting the 1082 for SNMP Management, the DTE rate

switches (S1-1,S1-2, and S2-1) must be also set to the ON posi-
tion. Therefore, to set a 1082 unit SNMP Mangagement mode, the
following switches have to be at the ON position, S1-1, S1-2, S2-1.

Switches S1-1 and S1-2: Data Rate

Use switches S1-1 and S1-2 to configure the asynchronous or synchro-
nous data rate of the Model 1082 and Model 1082/144. Each setting rep-
resents one synchronous data rate and one asynchronous data rate.

Note

The Model 1082 can also operate at the 19.2 kbps synchronous

rate, and the Model 1092/144 can also operate at the 144 kbps
synchronous rate. To operate at these rates, set switches S1-1
and S1-2 both to the OFF position and Switch S2-1 to the ON
position (see section , “Configuring DIP switch S2” on page 122
for a description of Switch S2-1).

If the S2-1 switch is positioned in the OFF position, the 128 kbps
sync data rate/0–38.4 kbps async data rate option is selected.

Switch S1-3: Data Set Ready during Line Loopback Test

Use Switch S1-3 to control the behavior of the DSR signal at the EIA
interface during the line loopback test.

S1-1

S1-2

Sync Data Rate

Async. Data Rate

On

On

32 kbps

Reserved

Off

On

56 kbps

Reserved

On

Off

64 kbps

Reserved

Off

Off

128 kbps (see note)

0–38.4 kbps

Off

Off

144 kbps or 19.2 kbps (see note)

Reserved

S1-3

Setting

On

DSR is on during local line loop

Off

DSR is off during local line loop