Table 2-1: Power Status Indications

Indicator

Color

Symptom

Remarks

Off

Internal power
supply unit is
unplugged or faulty

Internal power supply voltage is
too low.

Green

Indicates AC power
input active

Internal power supply voltage
is within tolerance.

AC

Orange

Internal problem
alarm

Built in Test (BIT) failed.

Table 2-2:

Port

Status Indications

Port LED Color

Port Load Conditions

Port Voltage

Off

Non-active load or
unplugged port.

Power to the port is disconnected. No
DC voltage present on spare pairs.

Green

Active load is plugged in
and complies with normal
load conditions.

Continuous nominal DC voltage is
present on the spare pairs.

Green blinks at a

1 sec. rate

Overload or short circuit.

Power to the port is disconnected.

No DC voltage is present on the spare
pairs.

Green blinks at a

0.5 sec. rate

Valid load.

Total aggregated power
exceeds pre-defined
power budget (400w by
default).

Power to the port is not connected or,
if previously connected –disconnected
at the moment.

No DC voltage is present on the spare
pairs.

Advertising