LINK LED This LED will turn ON when a valid connection has been established between the
CAB 16 and the network switch. This function is duplicated on the front panel.

ID The four digit number is the user-defined Hardware Base Address. The range is hex,
between 0000 and FFFF. The LED will turn ON when a valid number is entered. Each CAB
16 on the network must have a unique ID. If there is a duplicate, or the value is zero, this LED
will not light, and communications between the CAB and network is not valid.

METER INPUTS This switch along with the METER OUTPUT switch toggles the CAB
16d’s front panel audio meters between digital inputs and digital outputs. This function is
duplicated on the front panel of the CAB 16d.

DISABLE OUTPUTS This switch turns off the AES transmitters so that no valid AES data is
output from the box. This is different from Muting outputs in that muting stops audio data
but maintains valid AES output.

BUNDLE User defined number that assigns eight audio channels to a CobraNet

network

“bundle”. The range is OFF to 32,767. For switched networks, the number must be 256 or
higher. This number must also be set in the CobraNet I/O device for which the CAB will
transport audio. The LED is ON when the CAB 16d is receiving the specified network bundle.
Each CAB 16d can receive two separate audio bundles.

CHANNEL STATUS BLOCK Each audio bundle includes a Channel Status block. A single-
click in Control Mode, or a double-click in Edit Mode will open the block. When open, this
block contains status indicators and controls for digital audio performance parameters for
each audio bundle. The windows include separate functionality for input and output bundles.

CAB 16d Software Device Features