1.

SYMPTOM: THE SPA WILL NOT OPERATE

a. Check to see if the GFCI breaker is tripped or

was not turned on. Reset the GFCI breaker.

2.

SYMPTOM: THE CIRCUIT BREAKER OR THE
GFCI TRIPS WHILE THE SPA IS OPERATING

a. Reset the circuit breaker or the GFCI. If the cir-

cuit breaker or the GFCI trips again, contact a
qualified electrician for service.

Most problems can be solved by following the simple steps below. Find the symptom that applies, and
follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at
1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time.

Troubleshooting

CLEANING THE FILTER

The filter should be checked periodically for build-up of
dirt and oil. To check or clean the filter, follow the steps
below.

Cleaning the Basket:

1. Turn off the power.
2. Pull the Filter Door

(24) towards you
until it is fully open.

3. Reach into the

Basket (22) with four
fingers and pull the
Basket towards you
until it snaps free.

4. Lift the Basket out of

the housing by
pulling on the handle
on the far side and
turning the Basket
towards you.

5. Clean the Basket by

spraying it with a
garden hose or hold-
ing it under a faucet.
Avoid hitting the Basket against objects to
clean it, since this may break the basket.

6. Put the Basket back into the housing and press

down until it snaps into place.

7. Close the Filter Door.

Cleaning the Filter Cartridges:

1. Follow steps one

through four above
to remove the
Basket.

2. Reach into the hous-

ing and turn the
Diverter Valve (32)
until it is fully open.

3. Stick two fingers into

the holes in the Diverter (21) and lift the Diverter
and the top Filter Cartridge (10) directly upwards
until the edge of the Diverter clears the housing.
Then turn the Diverter towards you and pull it out.
In this process, the Diverter may come out of the
Filter Cartridge. If this happens, reach into the
housing and lift the Filter Cartridge out.

4. Remove the lower Filter Cartridge (10).
5. Clean the Filter Cartridges with a garden hose or

under a faucet. Spray from the top to the bottom of
each pleat. To avoid damage to the Cartridges,
do not use a brush to clean them.

6. To remove body oils or sun tan lotions, soak the

Cartridges in a cleaning solution which can be
obtained from a pool and spa supply store.

7. Inspect the Filter Cartridges for damage. Replace

the Cartridge if there is any sign of damage.

8. Put one Filter Cartridge back in the filter housing.
9. Push the tube on the Diverter into the other Filter

Cartridge as far as it will go. Place the top Filter
Cartridge back in the housing.

10. Put the Basket back into the housing and press

down until it snaps into place. Close the Filter
Door.

ADJUSTING THE DIVERTER

The diverter regulates the flow of water to the filter in
order to make the pump run smoothly. Start by leaving
the valve wide open. If the pump runs smoothly, no
further adjustment will be necessary.

If the pump begins to cavitate (if you hear a cracking
sound or if the speed of the pump surges up and
down), turn the valve slightly to reduce water flow.
Keep adjusting the valve in small increments until the
pump runs smoothly.

24